Practical Quality Class |Thursday night 430-hour leak alert: A near-mistaken delivery

Publisher:XiwitechRelease time:2026.11.16

Welcome to the "Xiao Q Quality Classroom" column! This column is carefully created by Xiwitech, focusing on sharing practical experience in quality management. Here, Xiao Q will become a hands-on expert, guiding everyone to use professional tools, break down real industrial scenarios, and explore solutions together!


This issue  

The lifespan data of 30 seals—whether to choose Weibull or log-normal—actually decides whether this batch of products can be delivered.


Three-line Conclusion:

First, among this batch of 30 complete failure life data points, the lognormal Anderson–Darling (0.945) performs better than the Weibull (1.675), making it a more suitable model for this set of candidates.


Second, the lognormal B10 point estimate is 648.00 h, which exceeds 600 h, but the 90% lower limit under normal distribution listed in the report is only 508.30 h; the Kaplan–Meier shows that after the third unit leaks at 690 h, the survival probability drops to 0.900. The empirical curve alone isn’t enough to independently justify release.


Third, a pause isn’t a veto: after completing the batch and assembly checks, and adding independent batch test units, use the same distribution to identify B10 and review the non-parametric lower tail as part of the evidence chain before deciding whether to restart customer validation.

*The data and conclusions are based on reproducible criteria from the supporting workbook. All test pieces have experienced their first leak, and a censor mark of 0 should not be used as a right-censored value.*


01.The call on Thursday night shift

Thursday night at 10 PM, the lab manager noticed while reviewing the constant temperature aging tests that the earliest hydraulic valve elastomer seal had its first leak at just 430 hours.  


According to the client's requirements, under the agreed aging and pressure conditions of around 110℃, the B10 life for the first leak should be at least 600 hours. Note, B10 is not the average life; it’s the time by which ‘10% of the products are expected to fail’—it represents the early failures that the client absolutely cannot have at their site.  


One phone call led to three different opinions:  

Manufacturing lead: Could be just a single assembly being off-center, an isolated case;  

R&D lead: The batch shows documented differences in mixing and curing, so a systematic issue can’t be ruled out;  

Lab manager: Rejecting a revised material solely based on a few early samples might miss the delivery window; but if we only look at average life or a curve that “seems to fit,” the client will face failure risk on-site.  


By 4 PM on Saturday, the quality lead must answer two questions:  


1. Which distribution best describes the lifetimes of these 30 units? Even if we pick the best fit, is the evidence for B10 enough to clear the 600-hour threshold?  

The first question decides how B10 is calculated, the second question decides whether we can proceed with client validation. This isn’t a math game—it’s the line between delivery and risk.


02.Why do we do distribution recognition here first?

The subject of this round of review is the revised rubber material: for two anonymous rubber batches, 30 seals from each batch were tested, recording the first leak time for each one. All 30 items in this round were complete failure records—there were no samples that stopped testing before leaking. So, we can first compare the life distributions and then use a distribution-free Kaplan–Meier survival estimate to check the lower tail.  


A few tools that are often misused need to be avoided here: control charts are concerned with process stability over time, capability analysis requires fixed specs and a stable process—neither can directly replace B10 life estimation; doing a mean t-test on the two rubber batches doesn’t answer the question about the 'bottom 10% failures'; DOE is suitable for the next round of intended experiments changing rubber, vulcanization, and assembly conditions—current observation records can’t be treated as a randomized experiment.  


In short: the choice of distribution determines the subsequent way to calculate B10. Weibull is commonly used for life data where the failure rate changes over time; lognormal describes right-skewed life caused by multiple cumulative multiplicative differences. Both need to go through fit diagnostics and business mechanism review—even if the fit metrics look good, B10 uncertainty still needs a separate check.


03.First, verify the lifespan standard

When reproducing the data, the test supervisor first did three 'unsexy but necessary' things:  

For each one, only the first leak was recorded, in hours; the case status was all marked as 'first leak', with censoring flag set to 0; the shelving order kept the chronological order, the rubber batch was labeled in Chinese, and the aging temperature was 110°C; confirmed that the timing zero point, leak threshold, pressure, and media conditions were consistent, and reviewed the test records and photos of the sealing surface and assembly at 430 h, 610 h, and 690 h.

图1.png

Figure 1 After importing Xiwitab, fields like individual lifespan and batch remain in Chinese


A key reminder: This batch of records doesn’t have right-censoring; the censoring mark is kept as 0 just to help readers understand the field scope. If you mistakenly mark a sample that is "not leaked but observation ended" as failed, it will lower the life estimate; if you mistakenly mark a sample that has already leaked as censored, it will inflate the survival probability. 0 should not be used as a right-censoring value.


04.Compare two survival curves in Xiwitab

After importing the workbook, first check the Chinese column names and 30 records, then select in order: 


Statistics → Reliability/Survival → Distribution Analysis (Right Censoring) → Distribution ID Plot


Set the variable as 'Time to First Leak (h)', choose Weibull and Lognormal, use Maximum Likelihood for estimation, and check the 10th percentile. (In the current version, even if you only tick these two, the results table may still list Normal and Exponential, so when judging, just refer to the two rows you planned to compare.)

图2.png

Figure 2 Distribution ID plot specifying Weibull and lognormal.


The results are out, and the two models gave different answers for the low end:

图3.png

Figure 3 Distribution Recognition Results: The log-normal fit statistics are low, and there's a clear difference in B10 between the two models.


For this set of candidate models and this batch of data, the log-normal fit is better. But if you just compare 648.00 h with 600 h, it ignores both model selection and estimation errors.


Then, in the 'Parameter Distribution Analysis', select the same variable, lognormal, maximum likelihood: 30 uncensored values, location parameter 7.24171, scale parameter 0.59913, log-likelihood −244.451. The B10 point estimate is 648.00 h, but the 90% normal lower limit listed in the report is only 508.30 h, which is below 600 h; the survival probability point estimate at 600 h is 0.9207, with a lower limit of 0.8379.

图4.png

Figure 4: The parameter report uses a log-normal distribution with maximum likelihood, all 30 items are uncensored values.


图5.png
Figure 5 Lognormal B10 is 648.00 h, with a 90% normal lower limit reported as 508.30 h


In plain terms: the point estimate went over the line, but the lower bound didn’t. You can’t treat a roughly 92% point estimate as a solid thumbs-up conclusion.


05.Don't let the model decide on its own

Check out Kaplan–Meier using 'nonparametric distribution analysis'—no need to preset Weibull or log-normal:

图6.png

Figure 6 Kaplan–Meier table shows that after the third item leaked at 690 hours, the survival rate dropped to 0.900


After the third leak at 690 h, the sample survival rate dropped to 90% for the first time. This point in time can be used as a reference for a lower-tail check.


Looking at the three pieces of evidence together:

 


The batch, assembly, and measurement calibers still need to be checked. The quality manager decided to suspend the customer validation submission for the revised rubber material and reassess the material after review.


06.Turn a pause into the next actionable step

Pause is not the end. Here's the action list to complete before the Saturday review:  

The lab supervisor should recheck the leakage thresholds, timing, pressure logs, and sealing surfaces of the first three items at the earliest; the manufacturing supervisor should trace the mixing, vulcanization, and dimension records of the corresponding rubber batches; if any test or assembly anomalies are found, events need to be redefined and analyses redone according to pre-defined rules, without just deleting unfavorable samples afterward. The reliability engineer should at least supplement test pieces from two independent rubber batches, unify the stop-test rules in advance, then repeat distribution identification, B10 parameter and non-parametric survival checks, and examine batch differences separately.  


Only if the rechecked low-tail results, the 90% lower limit in the report, and the failure mechanisms collectively support the 600-hour threshold can it be submitted again for customer verification. Since the customer’s site temperature, pressure fluctuations, and medium differ from test conditions, separate extrapolation or on-site verification is still needed. Going forward, rubber type, vulcanization temperature, assembly pressure, and their interactions should be differentiated, so a randomized DOE should be designed; if it enters stable mass production, control charts should be used to monitor process drift.

Return List

Schedule A Demo

Submit

Consulting Prices

Submit