Practical Quality Class |It runs fast at high temperatures, but does that mean it will last long at normal temperatures?

Publisher:XiwitechRelease time:2026.11.13

Welcome to the "Xiao Q Quality Classroom" column! This column is carefully created by Xiwitech, focusing on sharing practical experience in quality management. Here, Xiao Q will become a hands-on expert, guiding everyone to use professional tools, break down real industrial scenarios, and explore solutions together!


This Issue's Topic

Running fast at high temperatures, does that mean it will last enough at room temperature? — The B10 Question of 36 Potting Power Modules


A Sample Submission Decision Placed on the Table

In the packaging inspection lab of a large electronic component manufacturing company, the three-stage high-temperature test had just wrapped up: 110°C, 125°C, 140°C, with 12 potting power modules per stage, totaling 36 units. These modules will be installed into industrial control cabinets to provide continuous power to the controllers.


The customer's acceptance criteria are very specific: under 40°C operating conditions, the B10 life must be at least 20,000 hours. Here, B10 refers to the operating time when 10% of the products are expected to fail for the first time—the customer isn’t asking 'how long do they last on average,' but rather 'even the worst 10% shouldn’t fail too early.'


Looking at the data sheet, the first glance is tempting: the 110°C stage averages over 400 hours, 125°C around 310 hours, and 140°C about 130 hours. The higher the temperature, the faster they fail—a neat and straightforward pattern. It seems like you could just take an average, do some conversions, and figure out the life at 40°C.


This thought is precisely the most dangerous starting point.

The average can't answer B10's questions. The 9 samples that were stopped according to the plan only show that 'they lasted until they were stopped,' not that 'they won't fail.' To answer the customer's questions, you have to use a censored accelerated life model and extrapolate the high-temperature data to 40°C.


The data speaks for itself: the point estimate went past the line, and the lower bound is far from it.

Three temperature levels: out of 36 samples, 27 failed and 9 were right-censored. All of them went into the same model: a Weibull life distribution with an inverse temperature relationship—that is, Arrhenius logic, making the life scale vary with the reciprocal of absolute temperature. The response is 'operating time,' with censorship indicators distinguishing failures from planned stoppages. The estimation target is the 10th percentile at 40°C, with a 90% confidence level.  


The Xiwitab percentile table provides three key numbers:

B10 point estimate: 22,482 hours — slightly above the 20,000-hour threshold

Standard error: 18,457 hours

One-sided 90% lower limit: 7,851 hours


The point estimate does go beyond the client's threshold, but the lower bound reflecting the uncertainty of the estimate is less than 40% of the threshold. The further you extrapolate—from 110~140 ℃ down to 40 ℃, with a big temperature gap in between without data—the more trustworthy the lower bound of the interval is compared to the point estimate.


The point estimate is slightly above the threshold, but it can't prove that this batch of products meets the lifespan guarantee. According to the preset rules, the decision to send the sample has been postponed.



The model diagnostics also revealed another hidden risk: the adjusted Anderson-Darling fit statistics for the three temperature layers are about 22.967, 23.274, and 1.867—clearly too high for the first two layers. At the same time, the failure patterns at the highest temperature seem different from the other two. If 140℃ triggers a new failure pathway (like another degradation mechanism in the encapsulation material under extreme temperature), the assumption behind extrapolation, that 'the failure mechanism remains unchanged,' no longer holds. No matter how elegant the model is, it would be built on sand.


Original report fit parameters: Weibull shape 2.312, temperature option coefficient 763,619, intercept -13,382, log-likelihood -174.862, confirming that the model used 27 failures and 9 right-censored records.


Why do we have to use accelerated life testing?

Ordinary mean comparisons or linear regression treat planned test stops as regular endpoints, losing the information that 'the test could still continue after stopping'; fitting a Weibull for just one temperature level can't estimate the temperature slope; DOE is meant to serve the design of the next round of experiments and can't replace censored data analysis for this batch of completed life records.


The accelerated life model with temperature inversion can be written as:

ln(η(T)) = β₀ + β₁/(T+273.15)


Here, T is in Celsius, and η is the Weibull life scale. The model’s boundaries are also clear: all three high-temperature levels are well above 40 ℃, and the inverse temperature relationship is just a physical hypothesis to be tested. A single fitted line can’t prove that the failure mechanism hasn’t changed—you have to look at morphology checks, segmented fitting, and subsequent observations at lower temperatures together.

加速实验.png

Figure 1 Xiwitab 40 ℃ B10 Percentile Raw Report Screenshot

The three most common misjudgments during review

Misjudgment 1: Planned stop = proof that it’s not broken.

Not true. The samples stopped on purpose only provide information about 'it lasted at least this long' and must be entered into the model as censored data. Once the censoring mark is set incorrectly, the life estimate loses its original meaning.


Misjudgment 2: Just because a point estimate crosses the threshold doesn’t mean the lifetime is proven. 

A significant high-temperature fitting coefficient doesn’t mean the 40°C lifetime is confirmed. The further you extrapolate, the more you need to focus on the lower bound of the interval and the mechanistic evidence.


Misjudgment 3: Thinking that layering temperatures together = more convincing.
Merging might hide batch or morphology differences—if two batches are only run at different temperatures, batch differences could also masquerade as temperature effects. First, check the stratified records, then decide whether to keep a combined model.


After the delay, this is how to supplement the evidence



1.Mechanism check: Recheck the failed samples and morphology photos of the three levels to confirm that the definitions for outcomes like leakage are consistent; focus on checking the state of the encapsulation material at 140℃. If a new type of morphology is confirmed at the highest temperature, analyze that level separately, redesign the temperature gradient, and don’t use the original extrapolation as a basis for release. 


2.Supplement low temperature: In the next round, add observation points at temperatures closer to actual use, and keep long-term samples at 40℃. Arrange temperatures and clamping batches in a cross pattern to avoid mistaking batch differences for temperature effects; update failure, censoring, and morphology records weekly. 


3.Set a gate: Only when all three conditions are met — “the 40℃ single-side 90% lower limit reaches 20,000 hours, morphologies across the three levels are consistent, and no early counterexamples are observed in follow-ups” — should the customer verification batch be reconsidered.


Written at the end

This sample submission, which almost got approved, ultimately came to a stop in front of a percentile table.


Running fast at high temperatures doesn’t mean it will last long at normal temperatures. The only way to 'translate' high-temperature data back to normal conditions is with the right model, honest handling of censored data, and a lower bound that won’t be overshadowed by point estimates.


What clients really want isn’t a nice average number—they want a grounded assurance that they can use it with confidence.