Practical Quality Class | Why is the capability index still unstable even when multiple batches of raw materials are within specifications?

Publisher:XiwitechRelease time:2026.11.03

Xiao Q's Quality Classroom

Welcome to the "Xiao Q's Quality Classroom" column!

This column is carefully created by XiwiTech, focusing on sharing practical experience in quality management. Here, Xiao Q will take on the role of a hands-on expert, guiding everyone to use professional tools, break down real industrial scenarios, and explore solutions together.In the previous issue, we went through a detailed practical lesson for Practical Quality Course | Using Non-Normal Capability Analysis Methods to Assess the Service Life of Seals(click the blue text to review),This issue comes from: a new materials resin manufacturing plant, where the quality team has long been troubled by a 'weird problem.'

A tricky problem arose in the resin blending workshop of a new materials plant: all incoming resin batch viscosity tests met specifications, but as soon as they switched raw material batches, the finished product would easily show viscosity drift.

Different departments had different opinions: purchasing thought that all incoming materials were qualified and should be released; production reported that the batch center shifted within the compression process window; the lab suspected measurement artifacts caused by instruments or temperature control. With tight production time windows, the quality manager had to quickly decide whether to release or quarantine the batch.

Relying solely on 'pass/fail' could no longer pinpoint the root cause; it was necessary to separate random within-batch variations from systematic across-batch differences. This is where Xiwitab between-group/within-group capability analysis comes in handy.

Using Xiwitab between-group/within-group capability analysis, we can separate within-batch random variations from across-batch systematic differences:


Xiwitab actual baseline report: team capability is okay, but overall Ppk is pulled down by batch differences

Three-line conclusion

First, for the baseline 20 raw material batches, each had 6 viscosity measurements, with the engineering specs at 820/850/880 mPa·s; the Xiwitab report shows an overall Ppk=0.70, while the within-group Cpk=1.59.

Second, the single-factor ANOVA by batch gives F=410.23, P=0.00, indicating that the differences in batch means far exceed the within-batch noise. First, check the consistency of the formulation and incoming materials, rather than blaming random measurement fluctuations.

Third, after improvements using fixed temperature, fixed sampling, and batch means screening rules of 842-858 mPa·s, the overall Ppk for six validation batches is 7.24, within-group Cpk is 7.69, ANOVA F=2.03, P=0.10, achieving the preset closure condition.



01. On-site conflict: every batch passes, so why does the finished product's viscosity fluctuate after switching batches?

The viscosity testing sheet for incoming materials on the resin mixing line shows that each raw material batch in the baseline is within the engineering spec of 820-880 mPa·s; but complaints about the finished products always appear right after a batch change. Purchasing thinks 'if every batch passes, it should be released,' while production worries that a shift in the batch average could push the mixing window to the edge. The lab suspects that constant temperature timing or instrument drift might be creating false differences. The quality manager has to decide whether to release or quarantine the batch before the next mixing starts and lock in the decision by the 4:00 PM ingredient cutoff.

This time, it’s not just a simple matter of whether there’s an over-spec issue, but about two competing explanations: one is that differences in raw material batches or supplier mixing move the batch average; the other is that measurement noise, temperature conditions, or instrument instability within the same batch. The between-group/within-group capability analysis puts both kinds of variation into the same Xiwitab report, and ANOVA then checks whether the batch average differences exceed the within-batch error.

Table 1 Specifications, Sampling Structure, and On-Site Decisions

First, make sure the measurements are reliable. A viscometer needs a fixed temperature, a constant time, a rotor, and a calibrated state; only six readings from the same batch make a reasonable subgroup. If the reference material shows unstable repeated checks, you should first check repeatability, reproducibility, bias, and stability. You can't use the capability index to replace measurement system analysis.


02. Data reliability: You can't lose batch boundaries and chronological order

The worksheet keeps stages, raw material batches, supplier codes, constant temperature, sequence number within the batch, time order, and response columns. The six measurements for each batch are completed consecutively under the same constant temperature, with the row order following the delivery and testing order, without rearranging by viscosity. Batches are used as grouping fields for between- and within-group analysis, and suppliers and temperature provide context for tracing and competitive explanations. Time order is used to align delivery, constant temperature, and mixing records.

Figure 1 Xiwitab actual data table: batch grouping and measurement conditions retained simultaneously

Table 2 Data Dictionary and Statistical Roles

The spec tape is different from the screening tape. 820-880 mPa·s is the engineering spec—answer whether its use is allowed; 842-858 mPa·s is the batch average screening tape—answer whether the batch center leaves enough margin for downstream. We can't just make the engineering spec narrower because the screening tape is narrower.


03. Exploring the evidence: The batch is very narrow, but the center shifts between batches

First, summarize the averages and the within-batch ranges based on the raw material batches, then look at the official report. If the readings within each batch are very consistent but the batch averages are clearly different from each other, then 'increased random noise from the instrument' isn’t the main explanation. A more reasonable order to check things would be supplier mixing, batch formulation, receipt temperature, and temperature control execution. On the other hand, if the differences in batch averages disappear after accounting for temperature control conditions, then the lab conditions should be the primary focus.

Figure 2 Xiwitab actual ANOVA: batch mean differences are obviously much larger than within-batch errors

What does this chart change? ANOVA's P=0.00 doesn't mean 'a specific supplier is definitely the root cause'; it just indicates that batch means can't be explained solely by within-batch error. It shifts on-site priorities from 'repeatedly checking single readings' to 'looking at batch composition, supplier consistency, and incoming release rules'; temperature and instruments still need to be rechecked under fixed conditions.


04. Xiwitab Operation: First remove mutations, then check batch differences

1. Import and confirm fields: Import the supporting workbook, make sure viscosity_mPa_s is a numeric column, and the raw material batch is a grouping field; run the baseline and validation separately by phase, don’t mix the two stages into one process.

2. Check measurement conditions: First, check conditioning_temp_C, instruments, and thermostat records in chronological order; if the temperature or instruments don’t meet the freeze criteria, pause the capability assessment and go back to check the measurement system.

3. Open Between/Within Group Capability: Go to 'Statistics > Quality Tools > Capability Analysis > Between/Within Group', select the response as viscosity_mPa_s, arrange by single column, choose raw_material_lot for batch/subgroup, and set subgroup size to 6.

4. Enter Specifications: Fill in LSL=820, Target=850, USL=880 mPa·s; keep both overall and within/between group component outputs, and note the mean, standard deviation, and capability index from the report.

5.Run Batch ANOVA: Go to 'Statistics > ANOVA > One-way', set the response to viscosity_mPa_s, factor to raw_material_lot, significance level α=0.05; also review F, P, error standard deviation, and R-sq.

6. Screenshot After Hiding Data Area: After running, click the toggle at the bottom to minimize the data area, then capture the full chart and metrics; restore the data area only for continuing edits.

Figure 3 Xiwitab actual settings: subgroup size and specification frozen at the same time

Don't just look at one Cpk. Cpk mainly reflects short-term variation within the same batch, while overall Ppk also takes batch-to-batch shifts into account. If Cpk is high but Ppk is low, the conclusion isn't that the process is already good, but that it's stable within batches but unpredictable across batches. You should deal with batch strategies first.


05. Baseline results: The team's abilities passed the threshold, but overall capability has no margin for release

Figure 4 Xiwitab Actual Baseline Report: Batch Differences Dominate Long-Term Risk

Table 3 Baseline Xiwitab Between-Group/Within-Group Capability Results

Baseline decisions can't just let the next batch pass because "every batch meets specs." The overall Ppk=0.70 is below 1.33, which means there's not enough spec margin across batches. The batch ANOVA shows F=410.23 and P=0.00, pointing the action toward batch composition and supplier consistency, rather than reorganizing the measurement data or deleting high or low values.


06. Correct the action: turn the statistical signals into incoming material release rules

Before the next batch mix, the quality manager first screens the belts according to the batch average to make the release decision, while keeping the 820-880 mPa·s engineering spec unchanged. This step isn’t about pretending the screened belts meet spec; it’s about using a narrower batch center window to reduce downstream mixing risks. The supplier, lab, and process engineers are responsible for recording, measuring, and improving, respectively.

1.Isolation and confirmation: For incoming materials with batch averages not within 842-858 mPa·s, isolate them first and keep all 6 readings in order; don’t just keep a single qualified reading.

2. Review the measurement system: The lab supervisor should do repeated checks with reference materials to confirm that the temperature, holding time, rotor, calibration, and recording units are consistent; if measurement thresholds aren’t met, pause the capability conclusions.

3. Trace batch mechanism: The incoming material supervisor and supplier should check batch formulas, mixing time, storage temperature, and delivery conditions to confirm any suspicious mechanism in batch center movement.

4. Freeze release rules: Within the validation window, fix LSL=820, target=850, USL=880, batch mean between 842-858, and 6 samples per batch. Do not temporarily change the rules based on results.

5. Recording responsibilities and deadlines: The incoming materials supervisor records release/isolation decisions, the lab supervisor records temperature and retests, and the process engineer schedules six batches of validation once the supplier's corrections are completed.

Action boundaries: The abilities between and within groups and ANOVA support that 'batch differences should be the primary focus,' but they can't alone prove that a specific supplier's formula caused the change. To confirm causality, you should record temperature, formula, and mixing conditions before running regression or DOE; if the data shifts to failure time or warranty risk, switch to reliability/survival analysis.


07. Verification result: Six batches of new windows lowered both the overall and group risks at the same time

Figure 5 Xiwitab Actual Verification Report: Overall Ppk and Within-Group Cpk Both Exceed Acceptance Threshold

Figure 6 Xiwitab actual verification ANOVA: no obvious batch effect was observed at α=0.05

Table 4 Xiwitab Results of the Validation Window and Shutdown Conditions

Observations on closing the issue: All six batches met the criteria for capability, batch differences, and batch mean screening, which shows that the frozen release rules are effective within this validation window. Moving forward, we still need to continue spot checks under the same temperature, using the same instruments and the same sampling structure. Whenever there's a change in supplier, formula, or specification, a re-evaluation is needed.


08. Method Boundaries and Pre/Post Paths

Inter-group/intra-group capability analysis answers questions like 'How much of the variation is short-term within a batch versus long-term between batches, and is there any margin relative to the spec?' It can't replace measurement system studies, stability control charts, or causal experiments. Below, the methods are connected according to decision conditions; since there are no available external approved links, we'll just provide the method names, entry conditions, and the questions to answer.

Table 5 Connection rules for preceding and subsequent methods

Two important boundaries: First, when the process is unstable, the measurement system is unconfirmed, or the subgroup is unreasonable, you can't treat the capability index as proof for release. Second, just because the validation window looks great doesn't mean zero defects forever; the rules need continuous monitoring in subsequent batches, and if something goes off, you go back to the control chart and measurement system thresholds.


09. Common Pitfalls and Reproduction Entry Points

Common Pitfalls


The full verification of this sample data was carried out using Xiwitab, a professional statistical analysis tool developed by Xiwitech.

[Copyright Notice] This article is original analytical content. No organization or individual may reprint, excerpt, modify, or use it for commercial purposes without authorization. Please indicate the source if you need to quote it. If you need to reprint it, contact us for permission and indicate the source. Violators will be held legally responsible.