Practical Quality Class | Using Xiwitab to Grab SPC Tips with One Click!

Publisher:XiwitechRelease time:2026.10.28

Welcome to the “Xiao Q Quality Classroom” column!  

This column is carefully created by Xiwitech, focusing on sharing practical experiences in quality management. Here, Xiao Q will turn into a hands-on expert, guiding you to use professional tools, break down real industrial scenarios, and explore solutions together.  

SPC is one of the most commonly used statistical tools in manufacturing and is widely applied. However, during actual use, many people may feel that some operations are not smooth enough. In this issue, Xiao Q will combine firsthand frontline experience to share some practical SPC tips with you, helping you master SPC more easily and effectively!  

Packed with valuable content, so grab a notebook and follow Xiao Q!


01. How to Quickly Pick Out the 8 Major Principles of Differentiation

When creating SPC control charts, analysts often tend to overlook the combined application of various criteria for detecting anomalies. So, in practice, how can one quickly and accurately choose the right criteria? With Xiwitab, you can operate through the following steps:

At this point, after clicking, a screen will appear where all the options are checked, meaning all the exception rules apply.


02. How to show the A, B, C three sigma areas

To better see the actual placement of each sample, we usually need to display the three equal sections between the centerline and the upper and lower control lines. Here's a little trick for that, like in the Xiwitab operation interface:

After doing this, you can clearly display each sigma area in the Xiwitab screen, including areas A, B, and C. The effect is shown in the picture below:

The advantage of displaying it this way is that we can more intuitively compare it to the eight abnormality judgment principles (the mnemonic is: 2/3A, 4/5C, six in a row, eight has no C, nine single side, fourteen alternating, fifteen all C, one on the outside) to see exactly what type of abnormal point it is.


03. How to Choose the Right Algorithm for Control Limits

Everyone knows that different types of control charts have different formulas for control limits. For example, the XBAR-R control chart uses the range method for its control limits. At this point, we need to be careful not to select the wrong formula, otherwise the calculated control limits might not be accurate. The correct option in this case looks like this in the Xiwitab interface:

If we choose to merge the standard deviation here, the control limits we get will be different from the results when choosing Rbar. You can see the specific differences in the results below:

The first chart shows the control limits calculated using the R-bar method, and the upper control limit of its mean is 30.32.

The second chart shows the control limits calculated using the combined standard deviation method, and the upper control limit for its mean is 30.33.


The correct control limit value should be 30.32, because for XBAR-R control charts with a subgroup size <=5, the control limits are based on the range, so we need to go with the results from the first chart.


04. Summary and Conclusion

Textbooks often focus on the theory of SPC and lack guidance on applying it in specific situations. When we face complex situations in real work, we need to combine theoretical knowledge with on-site practice, flexibly adjust our analysis methods, and make the right judgments and choices. Only then can SPC truly become an effective tool for our quality management.